Menu
Cart 0

Defibtech Lifeline Fully-Auto AED | DCF-A120-EN

  • $1,295.00


Lifeline AUTO, The One-Button Defibrillator

The Lifeline AUTO is a fully automatic defibrillator designed to analyze heart rhythm and automatically deliver a shock – without intervention – if needed.

Simple, One Button Operation

Saving a life could not be easier: turn the unit on and the AUTO will do the rest. If the unit recognizes that a shock is needed, it will automatically shock the patient.

Clear Voice Prompts

Saving lives, while rewarding, can be stressful. A calm voice leads the user through the rescue, clearly and concisely stating each instruction, one step at a time. Brightly lit progress lights provide clear visual text guidance to reinforce voice instructions.

Long-life Battery

Two long life batteries are available: a 5 year battery that will deliver 125 shocks or work continuously for 8 hours or a 7 year battery, unique in the industry, which will deliver 300 shocks or work continuously for 16 hours.

Designed For the Real World

Lightweight, fully integrated design with no lids or moving parts that would confuse or delay a rescue; a roomy handle big enough even for gloved hands, and rubberized surfaces to ensure a sure grip in an emergency.

Automated or Automatic?  Automatic (shocks without user input)
AED Unit Warranty  Manufacturer's 8 year
Battery Warranty  Manufacturer's 4 year

 Defibtech Lifeline Auto AED Unit
 Soft Carry Case  One Set of Adult AED Pads
 Long Life Battery
 8-year Warranty
 User Manual & Quick Reference Card

      DEFIBRILLATOR

      TYPE
      Fully Automatic external defibrillator

      MODELS
      DDU-120A, DDU-120E

      WAVEFORM
      Biphasic Truncated Exponential
      (Impedance compensated)

      ENERGY
      Adult: 150 Joules
      Pediatric: 50 Joules
      (Nominal into 50 Ohm load)

      CHARGE TIME**

      DBP-2800: Less than 6 seconds
      DBP-1400: Less than 9 seconds

      **Typical, with new battery at 25º C

      VOICE PROMPTS
      Extensive voice prompts
      guide user through operation
      of the unit and CPR

      CPR PACING
      Metronome

      CONTROLS
      – Lighted On/Off button

      INDICATORS
      – “check pads”
      – “do not touch patient”
      – “analyzing”
      – armed-for-shock
      – AED status LED

      Self Tests

      AUTOMATIC
      Automatic daily, weekly and
      monthly and quarterly circuitry tests

      BATTERY INSERTION
      System integrity test on battery
      insertion

      PAD PRESENCE
      Pads preconnected tested daily

      USER-INITIATED
      Unit and battery pack system
      test may also be initiated by the
      user

      STATUS INDICATION
      Visual and audible indication of
      unit status

      Patient Analysis System

      PATIENT ANALYSIS
      Automatically evaluates patient impedance for proper pad contact. Monitors signal quality and analyzes patient ECG for shockable/non-shockable rhythms

      SENSITIVITY/SPECIFICITY
      Meets AAMI-DF-39 specifications and AHA recommendations

      Defibrillation / Monitoring Pads

      MODEL
      Adult – DDP-100
      Child/Infant – DDP-200P

      TYPE
      Pre-connected, single-use, non-polarized, disposable, self-adhesive electrodes with cable and connector

      SURFACE AREA
      103 cm2 (nominal, each pad)
      50 cm2 (nominal, each pad)

      PAD PLACEMENT
      Adult – Anterior/Anterior
      Child/Infant – Anterior/Posterior

      CABLE LENGTH (typical)
      48 in (122 cm)

      Environmental

      TEMPERATURE
      Operating: 0 to 50°C (32 to 122°F)
      Standby: 0 to 50°C (32 to 122°F)
      (with battery installed)

      RELATIVE HUMIDITY
      Operating / Standby: 5% – 95%
      (non-condensing)

      ALTITUDE
      -500 to 15,000 ft (-150 to 4500 m) per MIL-STD-810F 500.4 Procedure II

      VIBRATION
      Ground (MIL-STD-810F 514.5 Category 20)

      Helicopter (RTCA/DO-160D, Section 8.8.2, Cat R, Zone 2, Curve G)

      Jet Aircraft (RTCA/DO-160D, Section 8, Cat H, Zone 2, Curves B & R)

      SHOCK / DROP ABUSE TOLERANCE
      MIL-STD-810F 516.5 Procedure IV (1 meter, any edge, corner, or surface, in standby mode)

      SEALING / WATER RESISTANCE
      IEC60529 class IP54; Splash Proof, Dust Protected (Battery Pack installed)

      ESD
      EN61000-4-2:2009 (open air up to 15kV or direct contact up to 8kV)

      EMC (Emission)
      EN60601-1-2:2001 +A1:2006, limits EN55011:1998 +A1:1999 +A2:2002 Group 1 Level B, method

      EMC (Immunity)
      EN60601-2-4:2003, limits EN 61000-4-3:2002 Level 3 (10V/m), method

      Battery Pack

      TYPE
      – Lithium/Manganese Dioxide
      – Disposable, recyclable, non rechargeable

      LOW BATTERY INDICATORS
      – Visible
      – Audible

      MODEL DBP-2800

      POWER
      15V, 2800 mAh

      CAPACITY **
      – 300 shocks or 16 hours continuous operation

      STANDBY-LIFE**
      – 7 years

      MODEL DBP-1400

      POWER
      15V, 1400 mAh

      CAPACITY**
      – 125 shocks or 8 hours
      continuous operation

      STANDBY-LIFE**
      – 5 years

      **Typical, with new battery at 25º C

      Event Documentation

      INTERNAL EVENT RECORD
      Critical ECG segments and rescue event parameters are recorded and can be downloaded to a removable data card

      PC-BASED EVENT REVIEW
      ECG with event tag display, and audio playback when available

      REMOVABLE STORAGE
      (optional) Up to 12 hours of ECG and event data storage (no audio option) or up to 2 hours of audio, ECG and event storage (audio option) on a removable data card. Actual length of storage is dependent on card capacity.

      SIZE
      8.5 x 11.8 x 2.7 inches
      (22 x 30 x 7 cm)

      WEIGHT (Approximate)
      With DBP-1400: 4.2 lbs (1.9 kg)
      With DBP-2800: 4.4 lbs (2.0 kg)